AN IN VITRO RESEARCH EXAMINED THE RETENTION OF METALLIC AND NON-METALLIC DOUBLE CROWN RETAINED MANDIBULAR OVERDENTURES ON IMPLANTS

Main Article Content

Tanu Gupta
Ashish Choudhary
Prabhakar Gupta
Sachin Kumar

Keywords

Double-crown-retained mandibular overdentures, PEEK frameworks, Retention, Wear

Abstract

Purpose: To evaluate the change in the retention of novel metallic and non-metallic combinations for double-crown-retained mandibular overdentures on implants.


Methods: Cylindrical bases were used to insert four implants arranged in an arch, with 10 mm inter-implant spacing anteriorly, and 35 mm posteriorly. Five groups (n = 8 each) of different materials combinations were tested for retention: zirconia abutments/PEEK framework (ZP), PEEK abutments/ PEEK framework (PP), titanium abutments/PEEK framework (TP), titanium abutments/CoCr framework (TC), and titanium abutments/gold copings/cobalt-chromium framework as the control group (TG). The abutment retention height was 4 mm with 1° convergence angle.


Results: The initial median retention of all groups ranged from 10.0 to 33.3 N. After 10,000 insertion/separation cycles, the median retention ranged from 10.3 to 35.0 N. The change in the retention after 10,000 cycles was not statistically significant within groups ZP and TG. For groups PP and TP, there was a slight increase in retention with partial significance. The retention of group TC showed fluctuation with a partially significant decrease in retention.


Conclusions: The use of novel metallic and non-metallic combinations in the construction of double-crown-retained mandibular overdentures on implants resulted in acceptable levels of retention and might be recommended for clinical application.


 

Abstract 76 | pdf Downloads 64

References

1. Zafiropoulos GG, Rebbe J, Thielen U, Deli G, Beaumont C, Hoffmann O. Zir- conia removable telescopic dentures retained on teeth or implants for max- illa rehabilitation. Three-year observation of three cases. J Oral Implantol 2010;36(6):455–65.
2. Frisch E, Ziebolz D, Rinke S. Long-term results of implant-supported over- dentures retained by double crowns: a practice-based retrospective study af- ter minimally 10 years follow-up. Clin Oral Implants Res 2013;24(12):1281–7. doi: 10.1111/j.1600-0501.2012.02568.x.
3. Gurbulak AG, Kilic K, Eroglu Z, Gercekcioglu E, Kesim B. Evaluation of the retention force of double conical crowns used in combination with a gal- vanoforming and casting fabrication technique. J Prosthodont 2013;22(1):63–8. doi: 10.1111/j.1532-849X.2012.00897.x.
4. Minagi S, Natsuaki N, Nishigawa G, Sato T. New telescopic crown design for removable partial dentures. J Prosthet Dent 1999;81(6):684–8.
5. Rammelsberg P, Bernhart G, Lorenzo Bermejo J, Schmitter M, Schwarz S. Prognosis of implants and abutment teeth under combined tooth-implant- supported and solely implant-supported double-crown-retained removable dental prostheses. Clin Oral Implants Res 2014;25(7):813–18. doi: 10.1111/clr. 12197.
6. Verma R, Joda T, Brägger U, Wittneben JG. A systematic review of the clin- ical performance of tooth-retained and implant-retained double crown pros- theses with a follow-up of ≥3 years. J Prosthodont 2013;22(1):2–12. doi: 10. 1111/j.1532-849X.2012.00905.x.
7. Besimo C, Graber G, Flühler M. Retention force changes in implant-sup- ported titanium telescope crowns over long-term use in vitro. J Oral Rehabil 1996;23(6):372–8. \
8. Gungor MA, Artunc C, Sonugelen M. Parameters affecting retentive force of conus crowns. J Oral Rehabil 2004;31(3):271–7. doi: 10.1111/j.1365-2842.2004. 01036.x.
9. Ohkawa S, Okane H, Nagasawa T, Tsuru H. Changes in retention of various tele- scope crown assemblies over long-term use. J Prosthet Dent 1990;64(2):153–8.
10. Wöstmann B, Balkenhol M, Weber A, Ferger P, Rehmann P. Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance. J Dent 2007;35(12):939–45.
11. Kanbara T, Yajima Y, Yoshinari M. Wear behavior of tetragonal zirconia poly- crystal versus titanium and titanium alloy. Biomed Mater 2011;6(2):021001.
12. Bayer S, Kraus D, Keilig L, Golz L, StarkH, EnklingN. Wearof double crown systems: electroplated vs. casted female part. J Appl Oral Sci 2012;20(3):384–91.
13. Burns DR, Unger JW, Elswick RK Jr, Giglio JA. Prospective clinical evaluation of mandibular implant overdentures: Part II–Patient satisfaction and preference. J Prosthet Dent 1995;73(4):364–9.
14. Frisch E, Ziebolz D, Ratka-Krüger P, Rinke S. Double crown-retained maxillary overdentures: 5-year follow-up. Clin Implant Dent Relat Res 2015;17(1):22–31. doi: 10.1111/cid.12087.
15. Krennmair G, Suto D, Seemann R, Piehslinger E. Removable four implant- supported mandibular overdentures rigidly retained with telescopic crowns or milled bars: a 3-year prospective study. Clin Oral Implants Res 2012;23(4):481–8. doi: 10.1111/j.1600-0501.2011.02169.x.
16. Pietruski JK, Sajewicz E, Sudnik J, Pietruska MD. Retention force assessment in conical crowns in different material combinations. Acta Bioeng Biomech 2013;15(1):35–42.
17. Lucas LC, Lemons JE. Biodegradation of restorative metallic systems. Adv Dent Res 1992; 6:32–7. doi: 10.1177/08959374920 060 011301.
18. Engels J, Schubert O, Guth JF, Hoffmann M, Jauernig C, Erdelt K, et al. Wear behavior of different double-crown systems. Clin Oral Investig 2013;17(2):503–10. doi: 10.10 07/s0 0784- 012- 0746- 9.
19. Bayer S, Zuziak W, Kraus D, Keilig L, Stark H, Enkling N. Conical crowns with electroplated gold copings: retention force changes caused by wear and com- bined off-axial load. Clin Oral Implants Res 2011;22(3):323–9. doi: 10.1111/j. 1600-0501.2010.02003.x.
20. Weigl P, Hahn L, Lauer HC. Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 20 0 0;53(4):320–36.
21. Schwindling FS, Lehmann F, Terebesi S, Corcodel N, Zenthofer A, Ram- melsberg P, et al. Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial. Clin Oral Investig 2017;21(9):2653–60. doi: 10.10 07/s0 0784- 017- 2067- 5.
22. Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal im- plants. Biomaterials 2007;28(32):4845–69. doi: 10.1016/j.biomaterials.2007.07. 013.
23. Hahnel S, Wieser A, Lang R, Rosentritt M. Biofilm formation on the surface of modern implant abutment materials. Clin Oral Implants Res 2015;26(11):1297–301. doi: 10.1111/clr.12454.
24. Stock V, Wagner C, Merk S, Roos M, Schmidlin PR, Eichberger M, et al. Re- tention force of differently fabricated telescopic peek crowns with different tapers. Dent Mater J 2016;35(4):594–600.
25. Campbell SD, Cooper L, Craddock H, Hyde TP, Nattress B, Pavitt SH, et al. Removable partial dentures: the clinical need for innovation. J Prosthet Dent 2017;118(3):273–80.
26. Egusa H, Ko N, Shimazu T, Yatani H. Suspected association of an allergic reaction with titanium dental implants: a clinical report. J Prosthet Dent 20 08;10 0(5):344–7. doi: 10.1016/S0 022-3913.
27. Schwitalla AD, Spintig T, Kallage I, Muller WD. Flexural behavior of peek ma- terials for dental application. Dent Mater 2015;31(11):1377–84.
28. Wagner C, Stock V, Merk S, Schmidlin PR, Roos M, Eichberger M, et al. Re- tention load of telescopic crowns with different taper angles between cobalt- chromium and polyetheretherketone made with three different manufacturing processes examined by pull-offtest. J Prosthodont 2018;27(2):162–8.
29. Beuer F, EdelhoffD, Gernet W, Naumann M. Parameters affecting re- tentive force of electroformed double-crown systems. Clin Oral Investig 2010;14(2):129–35.
30. Di Felice R, Rappelli G, Camaioni E, Cattani M, Meyer JM, Belser UC. Ce- mentable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study. Clin Oral Im- plants Res 2007;18(1):108–13.
31. Sakai Y, Takahashi H, Iwasaki N, Igarashi Y. Effects of surface roughness and tapered angle of cone crown telescopic system on retentive force. Dent Mater J 2011;30(5):635
32. Romanos GE, May S, May D. Treatment concept of the edentulous mandible with prefabricated telescopic abutments and immediate functional loading. Int J Oral Maxillofac Implants 2011;26(3):593–7.
33. Haraldson T, Carlsson GE. Bite force and oral function in patients with osseoin- tegrated oral implants. Scand J Dent Res 1977;85(3):200–8.
34. Nakagawa S, Torii K, Tanaka M. Effects of taper and space settings of telescopic CE-TZP/A crowns on retentive force and settling. Dent Mater J 2017;36(2):230–5. doi: 10.4012/dmj.2016-258.
35. Besimo C, Guarneri A. In vitro retention force changes of prefabricated attach- ments for overdentures. J Oral Rehabil 2003;30(7):671–8.
36. Tannous F, Steiner M, Shahin R, Kern M. Retentive forces and fatigue resis- tance of thermoplastic resin clasps. Dent Mater 2012;28(3):273–8. doi: 10.1016/ j.dental.2011.10.016.
37. Passia N, Ghazal M, Kern M. Long-term retention behaviour of resin matrix at- tachment systems for overdentures. J Mech Behav Biomed Mater 2016; 57:88–94.
doi: 10.1016/j.jmbbm.2015.11.038.
38. Merk S, Wagner C, Stock V, Schmidlin PR, Roos M, Eichberger M, et al. Reten- tion load values of telescopic crowns made of Y-TZP and COCR with Y-TZP sec- ondary crowns: impact of different taper angles. Materials (Basel) 2016;9(5).
39. Bayer S, Stark H, Mues S, Keilig L, Schrader A, Enkling N. Retention force mea- surement of telescopic crowns. Clin Oral Investig 2010;14(5):607–11.
40. Petropoulos VC, Smith W. Maximum dislodging forces of implant overdenture stud attachments. Int J Oral Maxillofac Implants 2002;17(4):526–35.
41. Stock V, Schmidlin PR, Merk S, Wagner C, Roos M, Eichberger M, et al. PEEK primary crowns with cobalt-chromium, zirconia and galvanic secondary crowns with different tapers-a comparison of retention forces. Materials (Basel) 2016;9(3).