DOSE SPARING OF INDUCTION DOSE OF PROPOFOL BY FENTANYL AND BUTORPHANOL: A COMPARISON BASED ON ENTROPY ANALYSIS
Main Article Content
Keywords
.
Abstract
Introduction: Entropy monitoring is a method of assessing anaesthetic depth. There is abundant literature on the analgesic properties of butorphanol and fentanyl and its efficacy as an adjuvant to epidural and intra-thecal local anaesthetics, but not on dose sparing of induction dose.
Aim: The present study aims to compare the propofol requirement by fentanyl and butorphanol as pre-medication agent using entropy.
Methodology: The study was conducted on inpatients of hospitals attached to our institute for a duration of 18 months. This is a Prospective Randomized control trial that that included two groups, namely GROUP B included patients on Butorphanol [20 µg/kg] and GROUP F included patients on Fentanyl [2 µg/kg]. Seventy patients were randomly selected for each group, thus a total of 140 patients were included in the study.
Results: Response Entropy, State Entropy and Sedation score were comparable between group F and Group B without significant difference. The present study noted that Propofol requirement is comparable between group F and Group B without significant difference.
Discussion: Major drawbacks of anesthetic induction with propofol are a greater degree of cardiorespiratory depression as compared with other hypnotic agents and inadequate attenuation of the hypertensive response to intubation.
Conclusion: Butorphanol 20 μg/kg IV prior to the induction of anaesthesia reduces the induction dose of propofol, comparable to that of fentanyl 2 μg/kg IV and both the drugs are hemodynamic stable at induction and intubation.
References
2. Vakkuri A, Yli-Hankala A, Sandin R, Mustola S, Hoymork S, Talja P et al. Spectral entropy monitoring is associated with reduced propofol use and faster emergence in propofol - nitrous oxide - alfentanil anesthesia. Anesthesiology 103, 274-9 (2005).
3. Aimé, I, Verroust N, Masson-Lefoll C, Taylor G, Laloe PA, Liu N et al. Does monitoring bispectral index or spectral entropy reduce sevoflurane use? Anesthesia and Analgesia, 103(6), 1469–1477 (2006).
4. El Hor T, Philippe Van Der Linden, Stephen De Hert, Christian Melot, Javad Bidgoli. Impact of entropy monitoring on volatile anesthetic uptake. Anesthesiology, 118(4), 868–873 (2013).
5. Robert SK. Opioid agonists and antagonists. Chapter 3. In:Pharmacology and physiology in anaesthesia practice. 3rd edition. Lipincott Raven publishers; 1999; 77-112
6. Singh V, Pathak M, Singh GP. Oral midazolam and oral butorphanol premedication. Indian J Pediatr 2005; 72:741 4.
7. Vikramjeet Arora, Sukhmindar Jit Singh Bajwa, Sarajit kaur. Comparitive evaluation of recovery charateristeics of fentanyl and butorphanol when used as a supplement to propofol anaesthesia. Int J Appl Bsic Med Res. 2012 Jul-Dec; 2(2):97-101
8. Margret W, Alastain W. Opioid agonists and antagonists. Chapter 7. In:Drugs and anaesthesia pharmacology for anaesthesiologists, Williams and Wilkeins publishers, London, 2nd edition; 129-178.
9. Kaur J, Srilata M, Padmaja D, Gopinath R, Bajwa SJ, Kenneth DJ, et al. Dose sparing of induction dose of propofol and fentanyl: A comparison based on entropy analysis. Saudi J Anaesth 2013; 7:128-33
10. Riad, W, Schreiber, M, Saeed, A. B. Monitoring with EEG entropy decreases propofol requirement and maintains cardiovascular stability during induction of anaesthesia in elderly patients.European Journal of Anaesthesiology: August 2007 - Volume 24 - Issue 8 - p 684–688