MRI safety practices: Ensuring patient and staff well- being in the magnetic environment
Main Article Content
Keywords
“safety practice”, “magnetic resonance”, “patient safety”, “Quality”, “magnetic environment”.
Abstract
Developing a magnetic resonance imaging (MR) safety protocol is essential to guaranteeing patient and staff safety during MR imaging. A core safety council and a wider safety committee made up of all-important stakeholders are part of the organizational structure. Together, these groups strive to establish a strong safety policies and procedures, enforce device regulations for entry into the MR setting, build MR safety zones, address intraoperative MR concerns, ensure safe scanning parameters and guarantee appropriate communication among all parties involved in the MR environment.
Aim: The purpose of the current review is illustrating and understanding safety instructions and protocols for maintaining a good safety practice and ensure patient and staff well being safety in magnetic environment.
Method: A systematic review is maintained from electronic databases in English language and from published papers from 2009 to 2021.
Result: 13 articles was selected and reviewed based on inclusion criteria and focus on the various policies of safety practice to ensure patient and staff well-being safety in magnetic environment.
Conclusion: The literature that was retrieved indicates that safety guidelines for patient safety and staff well-being in magnetic environment have been established according to the current body of knowledge.
References
Johnston T, Moser R, Moeller K, Moriarty TM, (2009). Intraoperative MRI: Safety,Neurosurgery Clinics of North America,Vol 20, Issue 2, Pages 147-153.
Yong A, Kanodia AK, Wendy M, Pillai S, Duncan G, Serman A, Main G, Crowe E, Lorimer K, Heenan L, Johnston M, Villena M, MacFarlane JA, Sudarshan T, Guntur Ramkumar P. (2019). Developing patient-centered MRI safety culture: a quality improvement report. 1(1):20180011.
Crook N, Robinson L, (2009). A review of the safety implications of magnetic resonance imaging at field strengths of 3Tesla and above, Radiography, Volume 15, Issue 4, Pages 351-356.
Tsai L, Grant K, Mortele J, Kung W, and Smith P. (2015). A Practical Guide to MR Imaging Safety: What Radiologists Need to Know. 35(6) 1722-1737.
Kanal E, Barkovich AJ, Bell C et al (2013) ACR guidance document on MR safe practices: J Magn Reson Imaging 37(3):501–530
Hartwig V., (2015). Engineering for safety assurance in MRI: analytical, numerical and experimental dosimetry Volume 33, Issue 5, Pages 681-689
Romeo, S. Hartwig, V., & Zeni, O. (2018). Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches. Med Biol Eng Comput 56, 531–545
ICNIRP (2009) Guidelines on limits of exposure to static magnetic fields. Health Phys 96(4):504–514.
ICNIRP (2010) Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz). Health Phys 99:818–836.
EU (2013) Directive 2013/35/EU of the European Parliament and Of the Council of 26 June 2013 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields)
Kabil J, Belguerras L, Trattnig S, Pasquier C, Felblinger J, Missoffe A (2016) A review of numerical simulation and analytical modeling for medical devices safety in MRI. Yearb Med Inform 10(1):152–158.
Bottauscio O, Cassarà a M, Hand JW et al (2015) Assessment of computational tools for MRI RF dosimetry by comparison with measurements on a laboratory phantom. Phys Med Biol 60(14):5655–5680.
Batistatou E, Molter A, Kromhout H et al (2016) Personal exposure to static and time-varying magnetic fields during MRI procedures in clinical practice in the UK. Occup Environ Med 73:779–786.
Song T, Xu Z, Iacono MI, Angelone LM, Rajan S. (2018). Retrospective analysis of RF heating measurements of passive medical implants. 80: 2726–30.
Shellock FG. (2020). Reference Manual for Magnetic Resonance Safety, Implants, and Devices, 2020th edn. Biomedical Research Publishing Group,
Mittendorff L, Young A, Sim J, (2021). A narrative review of current and emerging MRI safety issues: What every MRI technologist (radiographer) needs to know 69 (2021) 250–260
Delfino JG, Krainak DM, Flesher SA, Miller DL. (2019). MRI-related FDA adverse event reports: A 10-yr review46: 5562–71.
U.S Food & Drug Administration. (2016) MAUDE adverse event report: MRI.
New Zealand College and Royal Australian of Radiologists. 2017. MRI safety guidelines version 2, Faculty of clinical radiology. Sydney, Australia.
Westbrook C, Talbot J. (2018). MRI in practice, 5th edn. Wiley/Blackwell, Hoboken, NJ,